| LED color temperature | 2700K* |
| Luminous flux | 2225 lm |
| Color rendering | CRI > 85 |
| IP Protection | IP 65 |
| application area | –40°C up to +55°C |
| Protection Class | I oder II |
| LED lifetime | >60.000 Hrs. |
| *LED color temperature freely selectable |
![]() |
![]() |
Polar diagram | Cartesian diagram |
| His.lux® Universalmodule 4 | ON/OFF | E1 | E2 | D1 | R1 |
| Module power in watts typical (at 350mA) | 36 | 6-36 | 6-36 | 6-36 | 6-36 |
| Regulatory capacity of output | |||||
| Manually via 10-stage Coding switch | X | X | X | ||
| Programmable via service unit | X | ||||
| Dimming | |||||
| Half-night switching over control voltage 230V dimming is selected manually using 10-stage Coding switch |
X | X | |||
| Multiple dimming steps programmable, astronomical dimming | X | ||||
| 0-10V / 1-10V interface | X | X | X | ||
| Dali / PWM interface (only if no control line is available) | X | ||||
| Special functions | |||||
| Constant light function (affects against the light loss) | X | ||||
| Light color typical * other color temperatures on request | |||||
| 2700K Warm white | X | X | X | X | X |
| 3000K Warm white | X | X | X | X | X |
| 3500K Warm white | X | X | X | X | X |
| Applied to | |||||
| For adjoining owner residential streets | X | X | X | X | X |
| For cycling and walking pathes, green areas | X | X | X | X | X |
| LED color temperature | 2700K* |
| Luminous flux | 4800 lm |
| Color rendering | CRI > 85 |
| IP Protection | IP 65 |
| application area | –40°C up to +55°C |
| Protection Class | I oder II |
| LED lifetime | >60.000 Hrs. |
| *LED color temperature freely selectable |
![]() |
![]() |
Polar diagram | Cartesian diagram |
| His.lux® Universalmodul | ON/OFF | E1 | E2 | R1 |
| Module power in watts typical (at 350mA) | 54 | 8-54 | 8-54 | 8-54 |
| Regulatory capacity of output | ||||
| Manually via 10-stage Coding switch | X | X | ||
| Programmable via service unit | X | |||
| Dimming | ||||
| Half-night switching over control voltage 230V dimming is selected manually using 10-stage Coding switch |
X | |||
| Multiple dimming steps programmable, astronomical dimming | X | |||
| 0-10V / 1-10V interface | X | X | ||
| Dali / PWM interface (only if no control line is available) | X | |||
| Special functions | ||||
| Constant light function (affects against the light loss) | X | |||
| Light color typical * other color temperatures on request | ||||
| 2700K Warm white | X | X | X | X |
| 3000K Warm white | X | X | X | X |
| 3500K Warm white | X | X | X | X |
| Applied to | ||||
| For adjoining owner residential streets | X | X | X | X |
| For cycling and walking pathes, green areas | X | X | X | X |
| LED color temperature | 2700K* |
| Luminous flux | 2400 lm |
| Color rendering | CRI > 85 |
| IP Protection | IP 65 |
| application area | –40°C up to +55°C |
| Protection Class | I oder II |
| LED lifetime | >60.000 Hrs. |
| *LED color temperature freely selectable |
![]() |
![]() |
Polar diagram | Cartesian diagram |
| His.lux® Universalmodul | ON/OFF | E1 | E2 | R1 |
| Module power in watts typical (at 350mA) | 27 | 4-27 | 4-27 | 4-27 |
| Regulatory capacity of output | ||||
| Manually via 10-stage Coding switch | X | X | ||
| Programmable via service unit | X | |||
| Dimming | ||||
| Half-night switching over control voltage 230V dimming is selected manually using 10-stage Coding switch |
X | |||
| Multiple dimming steps programmable, astronomical dimming | X | |||
| 0-10V / 1-10V interface | X | X | ||
| Dali / PWM interface (only if no control line is available) | X | |||
| Special functions | ||||
| Constant light function (affects against the light loss) | X | |||
| Light color typical * other color temperatures on request | ||||
| 2700K Warm white | X | X | X | X |
| 3000K Warm white | X | X | X | X |
| 3500K Warm white | X | X | X | X |
| Applied to | ||||
| For adjoining owner residential streets | X | X | X | X |
| For cycling and walking pathes, green areas | X | X | X | X |
| LED color temperature | 2700K* |
| Luminous flux | 2225 lm |
| Color rendering | CRI > 85 |
| IP Protection | IP 65 |
| application area | –40°C up to +55°C |
| Protection Class | I oder II |
| LED lifetime | >60.000 Hrs. |
| *LED color temperature freely selectable |
![]() |
![]() |
Polar diagram | Cartesian diagram |
| His.lux® Premiummodule | ON/OFF | E1 | E2 | D1 | R1 |
| Module power in watts typical (at 350mA) | 36 | 6-36 | 6-36 | 6-36 | 6-36 |
| Regulatory capacity of output | |||||
| Manually via 10-stage Coding switch | X | X | X | ||
| Programmable via service unit | X | ||||
| Dimming | |||||
| Half-night switching over control voltage 230V dimming is selected manually using 10-stage Coding switch |
X | X | |||
| Multiple dimming steps programmable, astronomical dimming | X | ||||
| 0-10V / 1-10V interface | X | X | X | ||
| Dali / PWM interface (only if no control line is available) | X | ||||
| Special functions | |||||
| Constant light function (affects against the light loss) | X | ||||
| Light color typical * other color temperatures on request | |||||
| 2700K Warm white | X | X | X | X | X |
| 3000K Warm white | X | X | X | X | X |
| 3500K Warm white | X | X | X | X | X |
| Applied to | |||||
| For adjoining owner residential streets | X | X | X | X | X |
| For cycling and walking pathes, green areas | X | X | X | X | X |